AVA6-50, 1-1/4″ HELIAX® Andrew Virtual Air™ Coaxial Cable

Request Pricing

Quantity:

SKU: AND-AVA650 Category:
Brand:

Description

AVA6-50, HELIAX® Andrew Virtual Air™ Coaxial Cable, corrugated copper, 1-1/4 in, black PE jacket

 

Product Classification  
Brand  HELIAX®
Product Series  AVA6-50
Product Type  Coaxial wireless cable
   


Construction Materials  
Jacket Material  PE
Outer Conductor Material  Corrugated copper
Dielectric Material  Foam PE
Flexibility  Standard
Inner Conductor Material  Corrugated copper tube
Jacket Color  Black
   


Dimensions  
Nominal Size  1-1/4 in
Cable Weight  0.46 lb/ft   |   0.68 kg/m
Diameter Over Dielectric  34.036 mm   |   1.340 in
Diameter Over Jacket  39.624 mm   |   1.560 in
Inner Conductor OD  14.0208 mm   |   0.5520 in
Outer Conductor OD  36.068 mm   |   1.420 in
   


Electrical Specifications  
Cable Impedance  50 ohm ±1 ohm
Capacitance  22.0 pF/ft   |   72.0 pF/m
dc Resistance, Inner Conductor  0.530 ohms/kft   |   1.740 ohms/km
dc Resistance, Outer Conductor  0.230 ohms/kft   |   0.750 ohms/km
dc Test Voltage  8500 V
Inductance  0.057 µH/ft   |   0.187 µH/m
Insulation Resistance  100000 Mohms•km
Jacket Spark Test Voltage (rms)  10000 V
Operating Frequency Band  1 – 3700 MHz
Peak Power  180.0 kW
Velocity  92%
   


Environmental Specifications  
Installation Temperature  -40 °C to +60 °C (-40 °F to +140 °F)
Operating Temperature  -55 °C to +85 °C (-67 °F to +185 °F)
Storage Temperature  -70 °C to +85 °C (-94 °F to +185 °F)
   


General Specifications  
Brand  HELIAX®
Ordering Note  CommScope® standard product in Asia Pacific   |   CommScope® standard product in the United States and Canada
   


Mechanical Specifications  
Bending Moment  29.8 N-m   |   22.0 ft lb
Flat Plate Crush Strength  75.0 lb/in   |   1.3 kg/mm
Minimum Bend Radius, Multiple Bends  203.20 mm   |   8.00 in
Minimum Bend Radius, Single Bend  152.40 mm   |   6.00 in
Number of Bends, minimum  15
Number of Bends, typical  40
Tensile Strength  154 kg   |   340 lb
   


Note  
Performance Note  Values typical, unless otherwise stated
   


Standard Conditions  
Attenuation, Ambient Temperature  68 °F   |   20 °C
Average Power, Ambient Temperature  104 °F   |   40 °C
Average Power, Inner Conductor Temperature  212 °F   |   100 °C

Return Loss/VSWR

Frequency BandVSWRReturn Loss (dB)
680–800 MHz1.1324.30
806–960 MHz1.1324.30
1700–2170 MHz1.1324.30

Attenuation

Frequency (MHz)Attenuation (dB/100 m)Attenuation (dB/100 ft)Average Power (kW)
0.50.0560.017117.01
10.0790.02482.63
1.50.0970.0367.41
20.1130.03458.33
100.2530.07725.89
200.360.1118.21
300.4430.13514.80
500.5760.17611.39
850.7580.2318.66
880.7720.2358.51
1000.8250.2517.96
1080.8580.2627.65
1501.0190.3116.44
1741.1020.3365.96
2001.1860.3615.53
2041.1980.3655.48
3001.4710.4484.46
4001.7170.5233.82
4501.8290.5583.59
5001.9370.593.39
5121.9620.5983.34
6002.140.6523.07
7002.3290.712.82
8002.5070.7642.62
8242.5480.7772.58
8942.6660.8132.46
9602.7740.8462.37
10002.8380.8652.31
12183.1710.9672.07
12503.2180.9812.04
15003.5691.0881.84
17003.8351.1691.71
17943.9551.2061.66
18003.9631.2081.66
20004.2121.2841.56
21004.3331.3211.51
22004.4521.3571.47
23004.5691.3931.44
25004.7981.4631.37
27005.0211.531.31
30005.3451.6291.23
34005.761.7551.14
37006.061.8471.08
  • * Values typical, guaranteed within 5%

Regulatory Compliance/Certifications

AgencyClassification
RoHS 2011/65/EUCompliant
China RoHS SJ/T 11364-2006Compliant
ISO 9001:2008Designed, manufactured and/or distributed under this quality management system
CENELECEN 50575 compliant, Declaration of Performance (DoP) available