LDF4-50A, 1/2″ HELIAX® Low Density Foam Coaxial Cable

Request Pricing

Quantity:

SKU: AND-LDF450A Category:
Brand:

Description

LDF4-50A, HELIAX® Low Density Foam Coaxial Cable, corrugated copper, 1/2 in, black PE jacket

 

Product Classification  
Brand  HELIAX®
Product Series  LDF4-50A
Product Type  Coaxial wireless cable
   


Construction Materials  
Jacket Material  PE
Outer Conductor Material  Corrugated copper
Dielectric Material  Foam PE
Flexibility  Standard
Inner Conductor Material  Copper-clad aluminum wire
Jacket Color  Black
   


Dimensions  
Nominal Size  1/2 in
Cable Weight  0.15 lb/ft   |   0.22 kg/m
Diameter Over Dielectric  12.954 mm   |   0.510 in
Diameter Over Jacket  15.875 mm   |   0.625 in
Inner Conductor OD  4.8260 mm   |   0.1900 in
Outer Conductor OD  13.970 mm   |   0.550 in
   


Electrical Specifications  
Cable Impedance  50 ohm ±1 ohm
Capacitance  23.1 pF/ft   |   75.8 pF/m
dc Resistance, Inner Conductor  0.450 ohms/kft   |   1.480 ohms/km
dc Resistance, Outer Conductor  0.820 ohms/kft   |   2.690 ohms/km
dc Test Voltage  4000 V
Inductance  0.190 µH/m   |   0.058 µH/ft
Insulation Resistance  100000 Mohms•km
Jacket Spark Test Voltage (rms)  8000 V
Operating Frequency Band  1 – 8800 MHz
Peak Power  40.0 kW
Velocity  88%
   


Environmental Specifications  
Installation Temperature  -40 °C to +60 °C (-40 °F to +140 °F)
Operating Temperature  -55 °C to +85 °C (-67 °F to +185 °F)
Storage Temperature  -70 °C to +85 °C (-94 °F to +185 °F)
   


General Specifications  
Brand  HELIAX®
Ordering Note  CommScope® standard product (Global)
   


Mechanical Specifications  
Bending Moment  3.8 N-m   |   2.8 ft lb
Flat Plate Crush Strength  110.0 lb/in   |   2.0 kg/mm
Minimum Bend Radius, Multiple Bends  127.00 mm   |   5.00 in
Minimum Bend Radius, Single Bend  50.80 mm   |   2.00 in
Number of Bends, minimum  15
Number of Bends, typical  50
Tensile Strength  113 kg   |   250 lb
   


Note  
Performance Note  Values typical, unless otherwise stated
   


Standard Conditions  
Attenuation, Ambient Temperature  20 °C   |   68 °F
Average Power, Ambient Temperature  40 °C   |   104 °F
Average Power, Inner Conductor Temperature  100 °C   |   212 °F

Return Loss/VSWR

Frequency BandVSWRReturn Loss (dB)
680–800 MHz1.1324.30
800–960 MHz1.1324.30
1700–2200 MHz1.1324.30
2300–2700 MHz1.1324.30

Attenuation

Frequency (MHz)Attenuation (dB/100 m)Attenuation (dB/100 ft)Average Power (kW)
0.50.1490.04540.00
10.2110.06436.11
1.50.2590.07929.46
20.2990.09125.50
100.6720.20511.35
200.9540.2917.99
301.1720.3576.51
501.5210.4635.02
851.9950.6083.82
882.0310.6193.76
1002.1690.6613.52
1082.2560.6883.38
1502.6730.8152.85
1742.8870.882.64
2003.1030.9462.46
2043.1350.9562.43
3003.8351.1691.99
4004.4621.361.71
4504.7491.4471.61
5005.0211.531.52
5125.0851.551.50
6005.5331.6861.38
7006.0091.8311.27
8006.4561.9681.18
8246.561.9991.16
8946.8552.0891.11
9607.1242.1711.07
10007.2842.221.05
12188.112.4720.94
12508.2262.5070.93
15009.0932.7710.84
17009.7442.970.78
179410.0393.060.76
180010.0583.0660.76
200010.6663.2510.72
210010.9613.3410.70
220011.2513.4290.68
230011.5353.5160.66
250012.093.6850.63
270012.6273.8490.60
300013.4074.0860.57
340014.4014.3890.53
370015.1184.6080.50
400015.8154.820.48
500018.015.4890.42
600020.0556.1130.38
800023.8267.2620.32
880025.2447.6940.30
  • * Values typical, guaranteed within 5%

Regulatory Compliance/Certifications

AgencyClassification
RoHS 2011/65/EUCompliant
China RoHS SJ/T 11364-2006Below Maximum Concentration Value (MCV)
ISO 9001:2008Designed, manufactured and/or distributed under this quality management system
CENELECEN 50575 compliant, Declaration of Performance (DoP) available